  Datasheet File OCR Text:
  series amer90-caz up to 3.75a | ac-dc / dc-dc | led driver / converter www.aimtec.com tel: +1 514 620 2722 toll free: + 1 888 9 aimtec (924 6832) f 052.1e r3.d 1 of 10 north america only features: models single output model max output power (w) output voltage range (v) ? output current (a) input voltage (vac/hz) input voltage (vdc) mode of operation efficiency (%) AMER90-50180CAZ 90 36-50 0-1.8 90-305/47-440 120-430 constant current 91 constant voltage 89 amer90-36250caz 90 24-36 0-2.5 90-305/47-440 120-430 constant current 90 constant voltage 88 amer90-24375caz 90 12-24 0-3.75 90-305/47-440 120-430 constant current 89 constant voltage 88 add suffix ?-f? no dimming option exceeding the maximum output power will permanently damage the converter the dimming feature is not supported when units are used in consta nt voltage mode only, aimtec suggests to order ?-f? no dimmin g option in this case. in constant current mode output current is maximum shown, in constant voltage mode output voltage is the maximum shown. note: all specifications in this datasheet are measured at an ambient temperature of 25c, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. input specifications parameters conditions typical maximum units inrush current <2ms 115vac 40 a 230vac 50 leakage current 115vac 0.5 ma 230vac 0.75 ac current 115vac 1.4 a 230vac 0.46 power factor 115vac 0.98 230vac 0.94 external fuse 250v/2.5a start up time 900 ms surge voltage 2sec 440 v output specifications parameters conditions typical maximum units current accuracy 3 % line regulation ll-hl 1 % load regulation 0-100% load 3 % ripple & noise 20mhz bandwidth 100 mv p-p hold-up time 100 ms current adjustment range 100-0 % minimum load voltage see the models table tested with 0.1f (c/c) or (m/c) and 47f (e/c) parallel capacitors at the end. ? constant current led driver or converter ? ? input range 90-305vac/47-440hz ? ? high efficiency up to 91% ? ? 115vac operating temperature -50 to 85c ? 230vac operating temperature -55 to 85c ? dimmable via analog / 0-10v dimming ? ? over current protection
series amer90-caz up to 3.75a | ac-dc / dc-dc | led driver / converter www.aimtec.com tel: +1 514 620 2722 toll free: + 1 888 9 aimtec (924 6832) f 052.1e r3.d 2 of 10 north america only isolation specifications parameters conditions typical rated units tested i/p-o/p voltage 3sec 3750 vac tested i/p-fg voltage 3sec 1880 vac tested o/p-fg voltage 3sec 500 vac isolation resistance 500vdc >1000 m ? isolation capacitance 1000 pf general specifications parameters conditions typical maximum units switching frequency 100 khz over current protection 110% of iout over voltage protection 110% of vout short circuit protection continuous short circuit restart auto recovery over temperature protection >105c operating temperature (see derating table) (115vac) -50 to +85 o c (230vac) -55 to +85 o c cold start-up time -55c 35 sec maximum case temperature 100 o c storage temperature -55 to +95 o c temperature coefficient 0.02 % / o c cooling free air convection humidity 95 % rh case material aluminum potting epoxy (ip68 rated) wires ul1015 18awg input & 14awg output *20cm weight 750 g dimensions (l x h x w) 7.13 x 2.32 x 1.85 inches 181.00 x 59.00 x 47.00 mm mtbf >400,000 hrs (mil-hdbk-217f at +25c) safety specifications parameters agency approvals ce standards en55022, class b, en60529(ip68), en61347-1, en61347-2-13 note: also designed to meet culus, ul8750, ul60950-1
series amer90-caz up to 3.75a | ac-dc / dc-dc | led driver / converter www.aimtec.com tel: +1 514 620 2722 toll free: + 1 888 9 aimtec (924 6832) f 052.1e r3.d 3 of 10 north america only dimensions analog (resistive) dimming application circuit model number maximum pot value (k ? ) AMER90-50180CAZ 11.70 amer90-36250caz 16.95 amer90-24375caz 28.09
series amer90-caz up to 3.75a | ac-dc / dc-dc | led driver / converter www.aimtec.com tel: +1 514 620 2722 toll free: + 1 888 9 aimtec (924 6832) f 052.1e r3.d 4 of 10 north america only 0-10v dimming application circuit temperature graph -55 -30 0204060 80 100 100 80 60 40 20 0 safe operating area output power (%) ambient temperature o c free air convection 64c 85c cv ? mode cc ? mode 230 vac 60c 80c
series amer90-caz up to 3.75a | ac-dc / dc-dc | led driver / converter www.aimtec.com tel: +1 514 620 2722 toll free: + 1 888 9 aimtec (924 6832) f 052.1e r3.d 5 of 10 north america only efficiency vs. input voltage and output current (cc mode) AMER90-50180CAZ amer90-36250caz
series amer90-caz up to 3.75a | ac-dc / dc-dc | led driver / converter www.aimtec.com tel: +1 514 620 2722 toll free: + 1 888 9 aimtec (924 6832) f 052.1e r3.d 6 of 10 north america only efficiency vs. input voltage and output current (cc mode) amer90-24375caz pfc value vs. output load current (cc mode) amepr90-50180caz
series amer90-caz up to 3.75a | ac-dc / dc-dc | led driver / converter www.aimtec.com tel: +1 514 620 2722 toll free: + 1 888 9 aimtec (924 6832) f 052.1e r3.d 7 of 10 north america only pfc value vs. output load current (cc mode) amer90-36250caz amer90-24375caz
series amer90-caz up to 3.75a | ac-dc / dc-dc | led driver / converter www.aimtec.com tel: +1 514 620 2722 toll free: + 1 888 9 aimtec (924 6832) f 052.1e r3.d 8 of 10 north america only constant current mode vs. constant voltage mode AMER90-50180CAZ amer90-36250caz
series amer90-caz up to 3.75a | ac-dc / dc-dc | led driver / converter www.aimtec.com tel: +1 514 620 2722 toll free: + 1 888 9 aimtec (924 6832) f 052.1e r3.d 9 of 10 north america only constant current mode vs. constant voltage mode amer90-24375caz output current vs. radj AMER90-50180CAZ
series amer90-caz up to 3.75a | ac-dc / dc-dc | led driver / converter www.aimtec.com tel: +1 514 620 2722 toll free: + 1 888 9 aimtec (924 6832) f 052.1e r3.d 10 of 10 north america only output current vs. radj amer90-36250caz amer90-24375caz note: 1. datasheets are updated as needed and as such, specifications ar e subject to change without notic e. once printed or downloaded , datasheets are no longer controlled by aimtec; refer to www.aimtec.com for the most current product specifications. 2. product labels shown, including safety agency cert ifications on labels, may vary based on the date manufactured. 3. mechanical drawings and specifications are for reference only. 4. all specifications are measured at an am bient temperature of 25c, humidity<75%, nominal input voltage and at rated output load unless otherwise specifie d. 5. aimtec may not have conducted destructive testing or chemical analysis on all internal components and chemicals at the time of publishing this document. cas numbers and other limited information are considered proprietary an d may not be available for release. 6. this product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control sys tems or other such applications which necessitate specific safety and regulatory standards ot her the ones listed in this datasheet. 7. warranty is in accordance with aimtec?s st andard terms of sale available at www.aimtec.com.


▲Up To Search▲   

 